All-In-One GPS Tracking Platform & Fleet Management System

Granit GPS Tracker Series: Technical Port 5112 Integration

The Granit protocol is a specialized communication standard primarily used via Port 5112 for telematics data. Whether you are using the compact C-100 or the rugged WP-30C, correct hardware wiring and software configuration are vital for real-time tracking accuracy.

G-100

1. Device Specifications Comparison

ModelDevice ClassEnvironment RatingSpecialization
C-100Compact/HiddenStandard IndoorAsset recovery & private vehicles
G-100Fleet ManagementStandard HousingMulti-purpose fleet logistics
L-100Logistics/CargoStandard HousingHigh-capacity data logging for long hauls
O-300Industrial/OBDEnhanced ProtectionHeavy machinery & CAN-bus telematics
WP-30CExtreme DutyIP67 WaterproofConstruction, marine, and open environments

2. Technical Wiring Diagram (Common Granit Interface)

POWER (+) [RED] ———————> 12V / 24V Constant DC Source
GROUND (-) [BLACK] ———————> Vehicle Chassis / Ground
IGNITION [WHITE] ———————> ACC / Ignition Switch (ON/OFF Sense)
FUEL CUT [YELLOW] ———————> Relay (Terminals 85/86 for Immobilization)
DIGITAL IN [GREEN] ———————> SOS Button / Sensor Input
ANALOG IN [BLUE] ———————> Fuel Level Sensor / Temperature Probe
 

3. SMS Configuration Commands (Port 5112)

Standard password is 123456. Send these to the device SIM number.

# Initialize the device
begin123456

# Set Server Address and Port 5112
adminip123456 123.123.123.123 5112

# Configure APN (Example: T-Mobile)
apn123456 ://t-mobile.com

# Set Reporting Frequency (Moving: 30s | Still: 10m)
fix030s010m***n123456

# Check Device Status
check123456

Atlantasys O-300

4. Troubleshooting: Fix “Offline” Status

  • Check SIM Credit/Data: Ensure the M2M SIM has an active data plan. Many “offline” issues are simply expired balance.
  • Validate GPRS Status: Send GPRS123456 to ensure the internet connection is active.
  • Check Signal Strength: Use the check123456 command. If the signal is below 15, relocate the antenna away from metal obstructions.
  • Verify Port Openings: Ensure your server firewall has TCP/UDP Port 5112 open. Use a tool like Packet Sender to verify communication.
  • LED Diagnostics:
    • Flashing Green: Searching for GSM signal.
    • Steady Green: Logged into GPRS network.
    • Flashing Blue: Searching for GPS satellites (Move outdoors).
  • Hard Reset: If the unit is frozen, send reset123456 or cycle the power physically.
Pro Tip: For WP-30C models used in marine or heavy rain environments, ensure the wiring harness entry point is facing downward to prevent water ingress via capillary action along the cables.